- OLED display with on-screen menu programming
- Fingerprint, PIN and RFID card access + Tuya app remote unlock
- 9,988 card/PIN + 500 fingerprints + 2 panic + 10 visitor users
- Temporary passwords via app; visitor codes valid 1–9 uses
- Anti-vandal zinc-alloy case, IP66, −40°C to 60°C
- Wide 12–28V AC/DC input; relay NO/NC/COM, 2A
- Door contact input, alarm output and doorbell contacts
- Two-door interlock and user copy between units
Price includes tax.
Cash on delivery all over Pakistan · Delivered in 2-5 working days
Why our price is lower
We import directly and supply the trade from two shops in Karachi and Lahore. There is no middleman between the container and you. Same product, fewer hands.
In stock, ready to ship
Limited stock1 year service warranty Void if burnt or physically damaged Claim it at either shop, or send it back — we handle the manufacturer for you. Invoice included with every order.
Will this fit my setup?
- Check the voltage your existing wiring or adaptor supplies.
- Measure the space, door thickness or bracket spacing before ordering.
- Confirm it works with the recorder, panel or app you already use.
- Still not sure? Send a photo of the old part, the door or the existing setup. We will tell you what fits - usually within minutes during shop hours.
Need this installed?
We don't just sell it — we fit it. ZZ Marts has been installing security and automation across Pakistan since 2005. Tell us about the site and we'll quote supply and installation together.
Get an installation quote- Free delivery on orders over Rs 5,000
- 2-3 working days to Karachi, Lahore and Islamabad · 3-5 elsewhere
- Cash on delivery available nationwide
- Order before 4pm for same-day delivery in Karachi and Lahore · prepaid orders only
- Save 4% when you pay by card or bank deposit · use code PREPAID4
- Free collection from our Karachi or Lahore shop
- Genuine product
- 7-day returns
- Secure checkout
- Trading since 2005
Not sure this is the right one? Ask us on WhatsApp - we will tell you straight.
Product details
Wiring (wire colours)
| Wire | Function | Notes |
|---|---|---|
| Red | AC/DC | 12–28V AC/DC regulated power input |
| Black | AC/DC | 12–28V AC/DC regulated power input |
| Grey & Black | GND | Negative pole |
| Blue & Black | Relay NO | Normally-open output — fail-secure lock (fit diode) |
| White & Black | Relay COM | Common for relay output |
| Green & Black | Relay NC | Normally-closed output — magnetic / fail-safe lock (fit diode) |
| Yellow | OPEN | Exit button (Request-to-Exit) input |
| Green | D0 | Wiegand Data 0 (pass-through) |
| White | D1 | Wiegand Data 1 (pass-through) |
| Grey | Alarm output | Negative contact for alarm/siren |
| Brown | Contact input | Door/gate contact (normally closed) |
| Brown & Black | Doorbell A | Contact for doorbell |
| Yellow & Black | Doorbell B | Contact for doorbell |
Connection guide
1. Standalone mode with a common power supply (factory default): Red and Black to the 12–28V AC/DC supply, Grey & Black to GND. Magnetic / fail-safe lock on Green & Black (NC) and COM; fail-secure lock on Blue & Black (NO) and COM, with lock power from the supply. Exit button between Yellow and GND; door contact between Brown and GND; alarm/siren − to Grey and + to +DC; doorbell to Brown & Black and Yellow & Black. Important: fit the supplied 1N4004 diode across the lock when sharing one power supply, or the keypad may be damaged.
2. With an access-control (special) power supply: Blue & Black (NO) → PSU PUSH, Red → +12V, Grey & Black → GND; lock powered from the PSU's NC / GND-COM / NO terminals; exit button, door contact and DC alarm as above.
3. Controller mode (factory default): add an external Wiegand reader on Green (D0), White (D1), +12V and GND — the unit still works as a standalone controller. Use a 1N4004 diode when sharing power.
4. Wiegand reader mode: connect to a third-party controller — Red +12V, Grey & Black GND, Green D0, White D1, Brown → LED (green LED control), Yellow → BZ (buzzer control). Most controller settings are disabled in this mode.
5. Copy users to another unit: link two same-series units by Red, Grey & Black, Green (D0) and White (D1); set the same master code on both; on the master unit go to Menu 4 → 6 Copy Users. A full 10,000 users takes about 5 minutes; users on the receiving unit are overwritten (cards & PINs).
6. Two-door interlock: wire two units (A and B) each with its own lock, exit button and door contact (required), sharing one DC supply. Enrol users on A, copy them to B, then enable Menu 3 → 6 Interlock on both. Door 1 only opens when door 2 is closed, and vice versa — ideal for banks, prisons and secure rooms.
Installation
- Remove the back cover from the unit.
- Drill 2 screw holes (A, C) and one cable hole (B) in the wall.
- Knock the supplied rubber bungs into holes A and C.
- Fix the back cover firmly with the flat-head screws.
- Thread the cable through hole B and attach the unit to the back cover.
Sound & light indication
| Status | LED | Buzzer |
|---|---|---|
| Standby | Red bright | — |
| Enter programming mode | Red shines | One beep |
| In programming mode | Orange bright | One beep |
| Operation error | — | Three beeps |
| Exit programming mode | Red bright | One beep |
| Door open | Green bright | One beep |
| Alarm | Red flashes quickly | Beeps |
Programming (on-screen menu)
Keys: 0–9 enter values / menu numbers; # (OK/▼) confirm or scroll down; bell = doorbell; * (M) = menu — short press goes back, long press returns to the main screen. Enter the system menu with * (Master Code) # — factory master code 123456. Press ▼ to select and long-press # to confirm.
User IDs: card/PIN 1–9988, panic 9989–9990, visitor 9991–10000, fingerprint 10001–10500.
| Menu | Setting | Options / notes |
|---|---|---|
| 1 | Change Admin | New master code, any 6 digits |
| 2-1 | Add Directly | Add users by entering PIN / card / fingerprint |
| 2-2 | Add by ID | Add a user to a chosen user ID |
| 2-3 | Add Visitor | ID # (1–9 uses) # read card, or ID # (1–9) # PIN # |
| 2-4 | Block Enrol | Choose first ID, set card count (1–200), read first card |
| 2-5 / 2-6 / 2-7 | Delete | Delete directly (PIN/card), by ID, or delete all users |
| 3-1 | Open Time | 0–100 s (default 5 s) |
| 3-2 | Access Mode | 1 Card, 2 PIN, 3 Fingerprint, 4 Card/PIN/Fingerprint, 5 Multi-user (max 9) |
| 3-3 | Alarm Time | OFF (default) / 1 / 2 / 3 min |
| 3-4 | Door Contact | OFF (default) / ON |
| 3-5 | Security Mode | OFF (default) / Lock dead — access denied 10 min after 10 failed attempts / Alarm after 10 failed attempts (silence with Master Code # or valid user) |
| 3-6 | Interlock | OFF (default) / ON |
| 3-7 | Collect Card | OFF (default) / ON — any card opens and is added |
| 3-8 | WG Format | Parity check off / on (default); PIN 4-bit (default) / 8-bit / 10-digit; EM ID 26 (26–44); Mifare IC 34 (26–58) |
| 3-9 | Working Mode | Controller (default, also standalone) / Reader |
| 4-1 | Sound | OFF / ON (default) |
| 4-2 | Red LED | OFF / ON (default) |
| 4-3 | Keys Backlight | OFF / ON / Auto (default — off after 20 s) |
| 4-4 | OLED Backlight | ON / 5 s / 10 s / 30 s (default) / 1 min |
| 4-5 | Unbind Machine | Unbind the device from the app (long-press #) |
| 4-6 | Copy Users | Transfer users to another unit |
| 4-7 | Factory Reset | Reset settings; enrolled users are kept |
Specifications
Zinc-alloy, silver & black, 145 × 68 × 25 mm, 500 g (615 g shipping); 12–28V AC/DC (≤150mA working, ≤60mA idle); one relay NO/NC/COM rated 2A, 0–99 s; IP66; −40°C to 60°C; 0–98% RH. Wiegand 26–44 bits (EM) and 26–44, 56, 58 bits (Mifare) input & output; PIN output 4-bit, 8-bit ASCII or 10-digit virtual number. Wiring: relay output, exit button, alarm, door contact, Wiegand input and output.
In the box: HT-F1-OLED unit, master card, 1N4004 diode (relay protection), wall anchors, self-tapping screws (Φ4 × 25 mm), screwdriver and user manual.
Specifications
| Model | HT-F1-OLED Display: OLED with touch keypad Connectivity: WiFi (Tuya app) User capacity: 9,988 card/PIN + 500 fingerprint + 2 panic + 10 visitor Unlock methods: Fingerprint, PIN, RFID card, app, temporary password Card type: EM 125KHz (EM + Mifare 13.56MHz on dual-frequency version) Card read range: 2–6 cm PIN length: 4–6 digits Operating voltage: 12–28V AC/DC Current: Working ≤150mA, idle ≤60mA Relay: 1 × NO / NC / COM, 2A max Open time: 0–100 s (default 5 s), or toggle Inputs/outputs: Exit button, door contact, alarm output, doorbell, Wiegand in/out Wiegand (EM): 26–44 bits (default 26) Wiegand (Mifare): 26–44, 56, 58 bits (default 34) PIN output: 4-bit, 8-bit ASCII, 10-digit virtual number Working modes: Controller/standalone, Wiegand reader, interlock Waterproof: IP66 Operating temperature: −40°C to 60°C Operating humidity: 0–98% RH Material / colour: Zinc alloy, silver & black Dimensions: 145 × 68 × 25 mm Weight: 500 g (shipping 615 g) Default master code: 123456 In the box: Unit, master card, 1N4004 diode, wall anchors, Φ4×25 mm screws, screwdriver, manual |
|---|
Specifications are provided by the manufacturer and may change without notice. Please confirm before installation.
Frequently asked questions
What is the HT-F1-OLED and how much does it cost?
How many users can it store?
Can it control two doors as an interlock?
What power supply does it need?
Is there a warranty and delivery?
Customer reviews
Reviews from people who bought this product from ZZ Marts.