{"product_id":"clotix-door-release-switch-infrared-sensor-no-touch-door-exit-button","title":"No Touch Door Release – Infrared Exit Sensor Switch","description":"\u003cul\u003e\r\n \t\u003cli data-start=\"242\" data-end=\"321\"\u003e\r\n\u003ch2 data-start=\"219\" data-end=\"240\"\u003e\u003cstrong data-start=\"222\" data-end=\"240\"\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\r\n\u003cul data-start=\"241\" data-end=\"795\"\u003e\r\n \t\u003cli data-start=\"241\" data-end=\"336\"\u003e\r\n\u003cp data-start=\"243\" data-end=\"336\"\u003e\u003cstrong data-start=\"243\" data-end=\"269\"\u003eHands-Free Activation:\u003c\/strong\u003e Opens door without physical contact using IR (infrared) sensing.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli data-start=\"337\" data-end=\"429\"\u003e\r\n\u003cp data-start=\"339\" data-end=\"429\"\u003e\u003cstrong data-start=\"339\" data-end=\"369\"\u003eImproved Hygiene \u0026amp; Safety:\u003c\/strong\u003e Prevents germ transmission; ideal for high-traffic areas.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli data-start=\"430\" data-end=\"520\"\u003e\r\n\u003cp data-start=\"432\" data-end=\"520\"\u003e\u003cstrong data-start=\"432\" data-end=\"464\"\u003eAdjustable Sensing Distance:\u003c\/strong\u003e Configurable detection range for accurate triggering.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli data-start=\"521\" data-end=\"605\"\u003e\r\n\u003cp data-start=\"523\" data-end=\"605\"\u003e\u003cstrong data-start=\"523\" data-end=\"548\"\u003eLED Status Indicator:\u003c\/strong\u003e Light signals active sensing and trigger confirmation.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli data-start=\"606\" data-end=\"691\"\u003e\r\n\u003cp data-start=\"608\" data-end=\"691\"\u003e\u003cstrong data-start=\"608\" data-end=\"638\"\u003eDurable Wall-Mount Design:\u003c\/strong\u003e Built for long-term commercial and industrial use.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli data-start=\"692\" data-end=\"795\"\u003e\r\n\u003cp data-start=\"694\" data-end=\"795\"\u003e\u003cstrong data-start=\"694\" data-end=\"737\"\u003eCompatible With Access Control Systems:\u003c\/strong\u003e Works with door locks, controllers, relays, and magnetic locks.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\n\u003cul\u003e\r\n \t\u003cli data-start=\"242\" data-end=\"321\"\u003e\r\n\u003cp data-start=\"838\" data-end=\"1195\"\u003eThe \u003cstrong data-start=\"842\" data-end=\"874\"\u003eNo Touch Door Release Switch\u003c\/strong\u003e is a contactless exit solution designed for access control systems where hygiene and convenience are critical. Using \u003cstrong data-start=\"992\" data-end=\"1023\"\u003einfrared sensing technology\u003c\/strong\u003e, the switch detects hand movement without requiring any physical contact, reducing the spread of germs and offering a clean, modern alternative to mechanical push buttons.\u003c\/p\u003e\r\n\u003cp data-start=\"1197\" data-end=\"1494\"\u003eWith adjustable sensing distance and LED indication for activation feedback, the switch provides reliable performance in commercial, industrial, and residential environments. It is widely used in offices, hospitals, schools, banks, and public facilities where hands-free door release is preferred.\u003c\/p\u003e\r\n\u003cp data-start=\"1496\" data-end=\"1831\"\u003eThis switch integrates easily with access control panels, electromagnetic locks, relay modules, and exit triggers. It is ideal for automatic doors, electric locks, maglocks, and secure access points. Designed for durability and stable performance, the No Touch Door Release is a reliable component for modern entry and exit automation.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003c!--zzmv2--\u003e\r\n\u003cp\u003e\u003cstrong\u003eA no touch exit button that never gets pressed.\u003c\/strong\u003e This is an infrared door release switch. Instead of pushing a button, you pass a hand in front of the sensor and the door releases. Nothing is physically touched, which means nothing wears out and nothing collects the marks and germs that a shared button accumulates in a busy building.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhy touchless exit buttons became standard.\u003c\/strong\u003e Demand rose sharply during COVID and never really fell back, because the hygiene argument turned out to be only half the benefit. The other half is durability. A mechanical push button on a hospital corridor or a busy office door is operated hundreds of times a day, and every one of those presses wears the mechanism. A touchless sensor has no moving parts to fail, so on high traffic doors it simply lasts longer. That is why hospitals, clinics, laboratories, food premises, and pharmaceutical facilities specify them as a matter of course.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhere it belongs.\u003c\/strong\u003e Hospital and clinic corridors, laboratories and clean rooms, food preparation and packing areas, pharmaceutical facilities, office lobbies and reception areas, and any high traffic internal door. Anywhere hygiene is a formal requirement, or where the sheer volume of use would destroy a mechanical button, this is the correct choice.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eIndoor placement matters, and here is why.\u003c\/strong\u003e Infrared sensing can behave unpredictably in strong direct sunlight, because sunlight contains infrared and can confuse the sensor into false triggering or reduced sensitivity. That makes this an indoor or sheltered device by nature. Corridors, lobbies, and internal doorways are ideal. If your door is fully exposed to afternoon sun or driving rain, tell us before ordering and we will recommend an outdoor rated alternative rather than let you fit the wrong thing.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eSetting the detection distance.\u003c\/strong\u003e Most infrared exit buttons allow the sensing range to be adjusted, and getting this right is what separates a device people like from one they complain about. Set too far, and the door releases every time someone walks past along the corridor without intending to leave. Set too close, and users end up waving repeatedly at the panel and pressing it anyway out of frustration. A short, deliberate range that requires an intentional hand movement is almost always correct.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eNO and NC wiring, the detail that goes wrong most often.\u003c\/strong\u003e Exit buttons are supplied with normally open and normally closed outputs, and which one you use depends entirely on the lock. Magnetic locks hold the door shut while powered, so releasing them requires the circuit to be broken, meaning an NC contact. Electric bolt and strike locks generally need the opposite. Wiring this backwards produces a door that either never releases or never locks, and it is the single most common installation error we see with exit devices. Tell us which lock you are pairing it with and we will confirm the correct configuration.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePower supply requirements.\u003c\/strong\u003e Unlike a simple mechanical button, an infrared sensor needs power to operate, typically 12V DC. That must come from your access control power supply, and the supply must be rated for the sensor as well as the lock and any other devices on the door. This is easy to overlook when replacing a mechanical button with a touchless one, and an undersized supply produces intermittent faults that are frustrating to diagnose.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhat happens during load shedding.\u003c\/strong\u003e Because the sensor needs power, it stops working when power does. What that means for the door depends on your lock. A magnetic lock releases when power fails, so the door opens and people can leave. A fail secure bolt lock stays locked, which means without backup power nobody can exit through that door using the button. For any door on an escape route this matters a great deal. Fit a backup supply or UPS, and make sure there is an emergency break glass release as well, so exit never depends on electronics being powered.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eIt is not a substitute for emergency egress.\u003c\/strong\u003e An exit button, touchless or otherwise, releases the door under normal conditions. Fire exits and escape route doors generally also require a break glass emergency release that works regardless of the state of the access control system or the power supply. If the door forms part of your escape route, ask us which combination your situation calls for; we would rather specify it properly than sell you a single component.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eMounting height and position.\u003c\/strong\u003e Fit it at a comfortable height for everyone using the door, typically around waist to chest level, on the secure side. Keep the cable in conduit rather than surface clipped, because an accessible exit button cable is an obvious way to release a door from outside. Position it where a person naturally approaches the door, not behind the door swing.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eTouchless or mechanical, choosing honestly.\u003c\/strong\u003e A plain push to exit button is cheaper, simpler, and completely reliable for a store room, a server room, or a door used by a handful of staff each day. There is no reason to pay more in those cases. Choose touchless where hygiene is a requirement, where traffic volume would wear a mechanical button out, or where the door is in a clinical or food environment.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eDoes it work in the dark?\u003c\/strong\u003e Yes. Infrared operation does not depend on ambient light.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eCan it be used outdoors?\u003c\/strong\u003e Not recommended in exposed positions because of sunlight interference and weather. Ask us about outdoor rated options.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eDoes it need its own power supply?\u003c\/strong\u003e Yes, typically 12V DC, shared with your access control supply and sized to include the lock.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWill it work with my magnetic lock?\u003c\/strong\u003e Yes, using the NC output. Confirm your lock type with us and we will specify the wiring.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eBuying from ZZ Marts.\u003c\/strong\u003e Available at our Karachi (Saddar) and Lahore stores with delivery across Pakistan, supplied by Zam Zam Traders, trading in access control and security hardware since 2005. We also stock mechanical push to exit buttons, stainless steel and metal faced buttons, emergency break glass releases, key operated switches, magnetic and bolt locks, power supplies, and access control keypads. Send us a photograph of your door and tell us which lock you are using, and we will confirm the correct exit device and wiring before you order.\u003c\/p\u003e\r\n\u003cp\u003eFitting a complete door system? See our \u003ca href=\"\/blogs\/guides\/access-control-system-price-pakistan-2026\"\u003eaccess control systems guide\u003c\/a\u003e to pair this no-touch exit button with the right lock and keypad.\u003c\/p\u003e","brand":"ZZ Marts","offers":[{"title":"Default Title","offer_id":52827954807096,"sku":"CMP-NO-TOUCH-DOOR","price":1850.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1012\/3932\/4984\/files\/ChatGPT-Image-Dec-20-2025-06_05_19-PM.png?v=1787211129","url":"https:\/\/zzmarts.com\/products\/clotix-door-release-switch-infrared-sensor-no-touch-door-exit-button","provider":"ZZ Marts | Zam Zam Traders","version":"1.0","type":"link"}