{"product_id":"380kg-magnetic-lock-no-nc-5-wire-heavy-duty-maglock-with-status-output","title":"380KG Magnetic Lock – NO\/NC 5 Wire Heavy Duty Maglock with Status Output","description":"\u003ch2 data-start=\"126\" data-end=\"143\"\u003eKey Features\u003c\/h2\u003e\r\\n\u003cp data-start=\"145\" data-end=\"420\"\u003e• Ultra Strong Holding Force: 380KG High Security\u003cbr data-start=\"194\" data-end=\"197\"\u003e• 5-Wire Output with NO\/NC\/COM Status Monitoring\u003cbr data-start=\"245\" data-end=\"248\"\u003e• 12V DC Operating Voltage\u003cbr data-start=\"274\" data-end=\"277\"\u003e• Fail-Safe Design (Unlocks When Power Is Off)\u003cbr data-start=\"323\" data-end=\"326\"\u003e• Heavy-Duty Aluminum Alloy Construction\u003cbr data-start=\"366\" data-end=\"369\"\u003e• Compatible with Advanced Access Control Systems\u003c\/p\u003e\n\n\u003cp data-start=\"454\" data-end=\"616\"\u003eThe \u003cstrong data-start=\"458\" data-end=\"496\"\u003e380KG NO\/NC Magnetic Lock (5 Wire)\u003c\/strong\u003e is a heavy-duty electromagnetic door lock designed for high-security installations requiring real-time door monitoring.\u003c\/p\u003e\r\\n\u003cp data-start=\"618\" data-end=\"771\"\u003eWith a powerful \u003cstrong data-start=\"634\" data-end=\"657\"\u003e380KG holding force\u003c\/strong\u003e, this maglock is ideal for main entrances, industrial facilities, corporate offices, and restricted access zones.\u003c\/p\u003e\r\\n\u003cp data-start=\"773\" data-end=\"995\"\u003eThe \u003cstrong data-start=\"777\" data-end=\"801\"\u003e5-wire configuration\u003c\/strong\u003e includes \u003cstrong data-start=\"811\" data-end=\"864\"\u003eNO (Normally Open), NC (Normally Closed), and COM\u003c\/strong\u003e outputs, allowing door lock status monitoring and integration with access control panels, alarm systems, and security controllers.\u003c\/p\u003e\r\\n\u003cp data-start=\"997\" data-end=\"1160\"\u003eOperating on \u003cstrong data-start=\"1010\" data-end=\"1020\"\u003e12V DC\u003c\/strong\u003e, this lock features a \u003cstrong data-start=\"1043\" data-end=\"1066\"\u003efail-safe mechanism\u003c\/strong\u003e, meaning it unlocks automatically during power failure to ensure emergency safety compliance.\u003c\/p\u003e\r\\n\u003cp data-start=\"1162\" data-end=\"1309\"\u003eManufactured with strong aluminum alloy housing, it delivers durability, corrosion resistance, and long-term performance in demanding environments.\u003c\/p\u003e\r\\n\r\\n\u003ch2 data-start=\"1980\" data-end=\"2002\"\u003ePackage Includes\u003c\/h2\u003e\r\\n\u003cp data-start=\"2004\" data-end=\"2044\"\u003e1 × 380KG Magnetic Lock (5 Wire NO\/NC)\u003c\/p\u003e\r\\n\u003cp data-start=\"2046\" data-end=\"2066\"\u003e1 × Armature Plate\u003c\/p\u003e\r\\n\u003cp data-start=\"2068\" data-end=\"2085\"\u003eMounting Screws\u003c\/p\u003e\r\\n\u003cp data-start=\"2087\" data-end=\"2108\"\u003eInstallation Manual\u003c\/p\u003e\r\\n\r\\n\u003c!--zzmv2--\u003e\r\\n\u003cp\u003e\u003cstrong\u003eThe heavy duty maglock, and when you actually need it.\u003c\/strong\u003e A 380kg holding force is specified for main entrance doors, heavy timber doors, and any opening where someone might realistically apply force. It is the strongest magnetic lock in our range and the right choice where the door is the primary barrier rather than an internal divider.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003eDo not simply buy the strongest.\u003c\/strong\u003e Holding force should match the door, not your anxiety about it. A light internal or glass partition door is well served by 180kg, and most standard commercial doors by 280kg. Fitting 380kg to a lightweight door achieves nothing except cost, because the door leaf or the frame will fail before the magnet does. Tell us the door material, width, and location and we will recommend a rating rather than the largest one.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003eWhat the five wire version adds.\u003c\/strong\u003e A basic maglock has two wires and simply holds or releases. This version adds a status output, meaning the lock reports whether it is actually magnetised and holding rather than the system assuming it is. That matters on doors that genuinely need to stay secure: your access control panel can detect a door that failed to lock and alert you, instead of leaving it open silently overnight. For a server room, stock room, or cash office, that feedback is worth paying for.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003eFail safe by design, and what that means here.\u003c\/strong\u003e A magnetic lock releases the instant power is lost. That makes it the correct choice for escape routes, because nobody can be trapped by it. It also means load shedding will open the door. If the door must stay secure through outages, plan a backup supply or UPS at specification stage rather than discovering the behaviour afterwards. Every maglock installation in Pakistan needs this decision made deliberately.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003eBrackets are not optional, and are the most common ordering mistake.\u003c\/strong\u003e The lock body mounts to the frame and the armature plate to the door, but how they mount depends entirely on your door. An inward opening door normally needs an L bracket. A frameless glass door needs a U bracket that clamps the glass. Outward opening doors, narrow aluminium sections, and double doors each need their own fitting. Ordering a maglock without the matching bracket is the single most common reason an installation stalls halfway through the day. Send us a photograph of your door and we will supply the right bracket with the lock.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003ePower supply sizing.\u003c\/strong\u003e Unlike a bolt lock, which only draws current when operating, a magnetic lock draws continuously for as long as the door is locked. Your power supply must be rated for that continuous load, and across several doors the figures add up quickly. An undersized supply produces intermittent faults that are genuinely difficult to diagnose after the fact.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003eNC wiring and the exit button.\u003c\/strong\u003e Because the lock releases when the circuit breaks, exit buttons and release devices are wired as normally closed. Getting this backwards produces a door that either never locks or never releases, and it is the most frequent wiring error on maglock jobs. Confirm contact types before wiring, particularly when combining a keypad, an exit button, and a break glass unit on the same door.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003eFire alarm interfacing.\u003c\/strong\u003e On escape routes the maglock should be wired so that a fire alarm activation cuts power and releases the door independently of the access control system. This is a basic life safety expectation rather than a refinement, and it is regularly missed when the fire panel and the access control are installed by different contractors at different times. We supply both, so we can make sure the two work together.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003eMaintenance that actually matters.\u003c\/strong\u003e Keep the magnet face and the armature plate clean. Anything between the two surfaces, whether dust, grit, or paint overspray, reduces holding force noticeably. Check periodically that the armature plate still sits flush and has not worked loose, since a slightly loose plate is the usual reason a lock feels weaker than its rating suggests.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003eWhich holding force do I need?\u003c\/strong\u003e Tell us the door material, width, and whether it is internal or a main entrance, and we will recommend rather than upsell.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003eWill it work on a glass door?\u003c\/strong\u003e Yes, with the correct U bracket or patch fitting. Confirm your glass thickness with us first.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003eWhat happens during load shedding?\u003c\/strong\u003e The door releases, because maglocks are fail safe by design. Fit a backup supply if the door must remain secure through outages.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003eDo I need the five wire version?\u003c\/strong\u003e Only if you want lock status feedback to your controller. For a straightforward door the standard two wire version is sufficient and less expensive.\u003c\/p\u003e\r\\n\u003cp\u003e\u003cstrong\u003eBuying from ZZ Marts.\u003c\/strong\u003e In stock at our Karachi (Saddar) and Lahore stores with nationwide delivery, supplied by Zam Zam Traders, trading in access control since 2005. We also stock 180kg and 280kg maglocks, L and U brackets, glass door fittings, electric drop bolt locks, exit buttons, break glass releases, power supplies, and access control keypads. Send a photograph of your door and we will confirm holding force, bracket, and power supply before you order.\u003c\/p\u003e","brand":"ZZ Marts","offers":[{"title":"Default Title","offer_id":52827972895032,"sku":"M380KG NO\/NC","price":12499.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1012\/3932\/4984\/files\/Electromagnetic-lock-hardware-set1-1_ca06fd33-9c8f-4bce-b4a9-cff187f65367.png?v=1787211256","url":"https:\/\/zzmarts.com\/products\/380kg-magnetic-lock-no-nc-5-wire-heavy-duty-maglock-with-status-output","provider":"ZZ Marts | Zam Zam Traders","version":"1.0","type":"link"}